Opens in a new tab

Backwater Valve vs. Check Valve: What’s the Difference?

General plumbing information
October 31, 2026

by David Balkan

A backwater valve and a check valve are not the same thing. Learn how each works, where it belongs, and how backflow preventers fit in, before you buy.

Backwater valve and check valve in basement

A check valve is a general part that lets water move one way and closes when it tries to reverse. A backwater valve is a check-style valve built for one job: keeping sewage from the street sewer out of your building’s drains. Many people use the two names for the same thing, and that can cause problems when you buy or approve work. A backflow preventer is a third device that protects your drinking water, not your drains. This guide explains how each one works, where it belongs, and which one you need.

Balkanplumbing
Protect Your Property From Sewer Backup
Balkan repairs sewer lines and water mains, helping homeowners and businesses address complex plumbing issues across New York City.

Visit Balkan

TL;DR

  • A check valve is used on pumps, sump discharge lines, and single branch lines.
  • A generic check valve is not a substitute for a backwater valve on a main sewer line.
  • In New York City, backflow prevention devices must be tested every 12 months by a certified tester.
  • Whether your property needs a backwater valve depends on NYC code and on whether your fixtures or drains are subject to overflow from the public sewer.
  • No valve fixes a collapsed or root-choked pipe. Have the line inspected first.

Table of Contents

Why the names get mixed up

Plumbers, hardware stores, and even our own guides use “backwater valve,” “sewer check valve,” and “flap valve” for the valve on a building sewer. When we say “sewer check valve,” we mean a sewer-rated backwater valve, not a generic check valve from the plumbing aisle. When you are buying or approving work, the difference matters, because the three devices do different jobs.

Here is how they compare:

Device What it protects Where it goes Typical trigger
Check valve A pump, a pipe run or a single branch line Pump suction or discharge, sump line, a branch drain Flow reversing in one line
Backwater valve Your building from sewer backup On the building sewer or on drains serving low fixtures Street sewer surcharge, heavy rain
Backflow preventer Your drinking water On the water supply, at cross-connections Pressure drop in the water main, contamination risk

What a check valve does

A check valve allows flow in only one direction and prevents backflow. It needs no handle or power, because the water opens and closes it.

The two main types

  • Swing check valves: A hinged disc swings open with flow and falls closed when it stops.
  • Lift check valves: A disc or piston lifts under inlet pressure and reseats when flow stops.

Orientation depends on the design, so follow the manufacturer’s instructions.

Where check valves actually belong

Check valves are everywhere in plumbing, including at pumps. A sump pump discharge line is the classic homeowner example. If water drains back into the sump pit after the pump shuts off, a check valve on the discharge pipe is the fix.

How to tell which way a check valve flows

Most check valves have an arrow on the body. The arrow shows the forward direction, the way the valve opens. Install one backward and it will not open when the pump runs. On a sump line, the arrow points away from the pump, toward the outlet.

What a backwater valve does

A backwater valve does the same basic thing, one-way flow, but for sewage. When the city sewer is overwhelmed, wastewater can push back up your sewer service line and out of the lowest drains in the building, such as a basement floor drain, a shower, or a laundry sink. A backwater valve has a flap that opens for normal outflow and swings shut when flow reverses.

NYC DEP says a backwater valve can prevent sewer water from backing up into your home through basement fixtures. Installation and upkeep affect whether the flap seals when you need it.

Why a generic check valve isn’t enough

Research from the Institute for Catastrophic Loss Reduction explains that inline check valves are always closed, sit on branch lines from specific fixtures, and are not suitable for main sanitary sewer lines. It also says a generic “check valve” should not be confused with a backwater valve.

There are practical reasons. Sewer lines carry solids, grease, and paper. NYC’s plumbing code requires a backwater valve, when fully opened, to have a capacity not less than the pipe it is installed in, with access to its working parts for service and repair.

Check valve and backwater valve differences

Normally open or normally closed

Backwater valves come in a few designs. A basic flap type relies on reverse flow to push it shut. Automatic versions close in response to rising water, and Balkan’s automatic valve does not use electricity. Some also offer a manual gate. Our guides on backwater valve types and on the automatic backwater valve explain each one.

One limit to keep in mind: a sewer check valve isn’t a perfect seal. Our sewer valve guide explains that check valves greatly reduce backwater but do not eliminate it, so they are meant for surcharges lasting a few hours.

Balkan Sewer & Water Main Service - Joseph L. Balkan Inc., 86-45 130th Street, 11418 New York
Balkanplumbing
Discuss Sewer Backup Protection In Person
Visit Balkan to discuss sewer line concerns with a company specializing in sewer repairs, water main work, and complex plumbing issues.
Balkan Sewer & Water Main Service – Joseph L. Balkan Inc.
86-45 130th Street, 11418 New York

Get directions

Where the backflow preventer fits

A backflow preventer protects drinking water, not drains. NYC DEP says New York State law requires certain properties and businesses to install, maintain, and test these devices. Its examples include properties with in-ground irrigation sprinklers or swimming pools, hospitals, laundries and dry cleaners, supermarkets, and schools.

A double check valve assembly is one approved type, so a backflow preventer can be a check valve with more safeguards and a regulated test schedule.

Backflow devices must be tested

In New York City, a Professional Engineer or Registered Architect prepares the plan, a Licensed Master Plumber installs the approved device, and a New York State certified tester performs the initial test. After that, DEP says the device must be tested every 12 months, and failure to do so could result in fines or disconnection of your water service. DEP’s rules also list an air gap as an approved option for hazardous premises. An air gap has no moving parts, just open space.

Testing is part of the deal — overview diagram

Side by side: which one do you need?

Use this as a quick decision guide:

  • Water backs up through a basement floor drain or low fixture during heavy rain? You are asking about a backwater valve.
  • Water drains back into a sump pit after the pump stops? You need a check valve on the discharge line.
  • You have in-ground irrigation, a swimming pool, or a commercial water connection? NYC DEP may require a backflow preventer, and it must be tested.
  • Slow drains or recurring backups even on dry days? Skip the valve for now. The problem may be in your own pipe.

Does every house need a backwater valve?

No. NYC’s plumbing code requires accessible backwater valves where fixtures, floor drains, or area drains are subject to overflow from public sewer backwater. Buildings in special flood hazard areas are treated as subject to that overflow. Have a licensed plumber confirm what applies to your building and your fixtures’ height relative to the street sewer. NYC DEP also suggests contacting a plumber to decide whether a backwater valve makes sense for your home.

The risk comes from elevation: if your lowest drain sits below the level the street sewer can rise to, gravity works against you in a surge.

Installation and upkeep

Access and maintenance affect how well a backwater valve works.

  • Keep it reachable. NYC’s code requires access to the working parts for service and repair. Balkan installs its valves in a watertight access pit with a cover.
  • Put it in the right place. NYC’s code places it downstream of the building trap, and we install it on the street side of the house trap.
  • Check your system first. On combined sewers, or where rain drains feed the house sewer, rainwater has nowhere to go once the valve closes. Have a licensed plumber review the system before installation.
  • Inspect it. P&M advises checking the flapper for debris quarterly and after heavy rainstorms, and not running a snake through the valve. Clean a check valve every year or so.
  • Stop using basement fixtures while it is closed. NYC DEP says not to use them while the valve is closed.

We cover the installation side in our walkthrough on how a sewer trap and backwater check valve are professionally installed, and the reasons behind the device in how a sewer valve stops city sewer backups.

Our perspective: valve first, or pipe first?

A backup is not always caused by the city sewer. It can come from a root-choked or collapsed private line or a broken house trap. A valve will not fix a blocked or broken line.

So we start with a camera inspection. If the city sewer is surcharging and your fixtures are low, a properly sized, accessible backwater valve can be a smart layer of protection. If your own pipe is failing, the money belongs in repair or replacement, and the valve can be added as part of that job.

Do not let anyone install a generic check valve on a main sewer and call it a backwater valve. Ask for a valve meant for sewer use.

What a valve can’t do

Be realistic about the limits:

  • It doesn’t stop groundwater, surface runoff, or water coming through walls, windows, or foundation cracks.
  • It doesn’t clear a blocked or broken line.
  • A flap jammed open with debris will not protect you.
  • It is one layer. Good drainage and a sound sewer service line matter too.

If you’re in the middle of a backup, our page on what to do during a city sewer backup from heavy rain covers the safety steps. Keep out of standing sewage water, shut off electricity to flooded areas only if you can do so safely, and call a professional. In NYC, report sewage backing up into your home to 311.

When to call us

If you own or manage property in New York City and a valve question has turned into a pipe question, that’s our work. We inspect the line, explain what we see, handle sewer repair and replacement, and help with DEP notices, with a 10-year unconditional guarantee on full water or sewer line replacements. Our sewer repair page lists a typical range of $6,000 to $15,000, barring unusual circumstances. For a full line problem, see sewer line replacement. If water is already coming in, use our emergency sewer and water main service, available around the clock.

FAQ

What is the difference between a backwater valve and a backflow preventer?

A backwater valve sits on a drain or sewer line and stops sewage from flowing back into your building. A backflow preventer sits on the drinking-water supply. They protect opposite sides of your plumbing, and neither replaces the other.

Can I use a regular check valve instead of a backwater valve?

Not on a main sewer line. Inline check valves are suited to branch lines, and research from the Institute for Catastrophic Loss Reduction says they are not suitable for main sanitary sewer lines. Use a valve meant for sewer use, and make sure its working parts are accessible.

What are the two main types of check valves?

Swing and lift. A swing check uses a hinged disc that opens with flow and closes by gravity or reverse flow. A lift check raises a disc or piston off its seat under pressure and lowers it when flow stops.

Does every house have a backwater valve?

No. In NYC, the requirement turns on whether fixtures or drains are subject to overflow from the public sewer. Ask a licensed plumber or the NYC Department of Buildings what applies to your address.

Sources

 

David Balkan

David Balkan is the CEO of Balkan Sewer And Water Main, the largest and most trusted service in New York City. David is extremely active in various NYC plumber organizations being the Chairman of the Subsurface Committee in the Master Plumbers Council, and Vice President of the Subsurface Plumbers Association. In addition David’s expertise is respected by officials of New York City agencies such as the NYC DEP, NYC DOB, and the NYC DOT. He frequently provides valuable input on a variety of industry related matters.

Ready to Get Your Sewer or Water Main Issue Fixed?

Get An Instant Quote
  • We manage every project from start to finish
  • We work quickly with instant quotes & rapid responses
  • We are licensed as a Master Plumber
  • Our GPS fleet ensures we are on time, every time
  • We are available 24/7 for emergencies
  • We back all replacements with a 10-year unconditional guarantee